Linear Actuator Speed Chart: 3 mm/sec to 400 mm/sec
Compare the speed of every Purlin electric linear actuator in mm/sec, in/sec and in/min, and see how long each one takes to travel its stroke. From a 3 mm/sec high force actuator to the 400 mm/sec PAI-17.
Linear actuator speed chart
No-load rated speed of every model in mm/sec, inches per second and inches per minute, with the time to travel a 300 mm stroke. Speed under full load is lower; ask us for the load-speed curve of your model.
| Model | mm/sec | in/sec | in/min | Force (N) | 300 mm stroke takes |
|---|---|---|---|---|---|
| PAI-01-V1-3mm/sec | 3 | 0.12 | 7.1 | 6000–8000 | 100 s |
| PAI-01-V2-7mm/sec | 7 | 0.28 | 16.5 | 4000 | 43 s |
| PAI-16-V1-7mm/sec | 7 | 0.28 | 16.5 | 2000 | 43 s |
| PAI-36-V1-8mm/sec | 8 | 0.31 | 18.9 | 8000 | 38 s |
| PAI-01-V3-10mm/sec | 10 | 0.39 | 23.6 | 3500 | 30 s |
| PAI-02-V1-10mm/sec | 10 | 0.39 | 23.6 | 4000 | 30 s |
| PAI-01-V4-14mm/sec | 14 | 0.55 | 33.1 | 2000 | 21 s |
| PAI-02-V3-18mm/sec | 18 | 0.71 | 42.5 | 2000 | 17 s |
| PAI-01-V5-20mm/sec | 20 | 0.79 | 47.2 | 1300 | 15 s |
| PAI-02-V2-20mm/sec | 20 | 0.79 | 47.2 | 1500 | 15 s |
| PAI-16-V2-28mm/sec | 28 | 1.10 | 66.1 | 300 | 11 s |
| PAI-01-V6-30mm/sec | 30 | 1.18 | 70.9 | 1000 | 10 s |
| PAI-36-V3-30mm/sec | 30 | 1.18 | 70.9 | 500 | 10 s |
| PAI-01-V7-40mm/sec | 40 | 1.57 | 94.5 | 800 | 8 s |
| PAI-16-V3-48mm/sec | 48 | 1.89 | 113.4 | 100 | 6 s |
| PAI-01-V8-50mm/sec | 50 | 1.97 | 118.1 | 500 | 6 s |
| PAI-36-V4-50mm/sec | 50 | 1.97 | 118.1 | 200 | 6 s |
| PAI-01-V9-64mm/sec | 64 | 2.52 | 151.2 | 300 | 5 s |
| PAI-36-V5-80mm/sec | 80 | 3.15 | 189.0 | 100 | 4 s |
| PAI-01-V10-100mm/sec | 100 | 3.94 | 236.2 | 200 | 3 s |
| PAI-36-V2-200mm/sec | 200 | 7.87 | 472.4 | 3000 | 2 s |
| PAI-17-400mm/sec | 400 | 15.75 | 944.9 | 200 | 1 s |
All models: 24VDC, IP54, inbuilt limit switches, 10% duty cycle, made in Bengaluru. 12VDC on request.
Converting in/min and in/sec
Many datasheets quote speed in inches per minute. 1 in/min = 0.42 mm/sec, and 1 mm/sec = 2.36 in/min. So an 8.4 in/min actuator moves about 3.6 mm/sec, a 9 in/min actuator about 3.8 mm/sec, and a 0.22 in/sec actuator about 5.6 mm/sec. The nearest Purlin models are the PAI-01-V1-3mm/sec (7.1 in/min) and PAI-01-V2-7mm/sec (16.5 in/min).
Slow, medium and fast actuators
- Slow, high force (3–10 mm/sec): lifting heavy frames, hospital beds, presses and gates. See heavy duty.
- Medium (14–30 mm/sec): recliners, standing desks, hatches and medical chairs.
- Fast (40–400 mm/sec): sorting gates, vending machines, flaps, food machines and automation. See high speed linear actuators; the PAI-17 reaches 400 mm/sec.
Controlling speed
On a DC linear actuator the speed follows the voltage, so a PWM speed controller or a control box with soft start and soft stop can slow the actuator down. It cannot make it faster than its rated speed; for that choose a faster model. Two actuators moving one load should run from a synchronised control box.
Frequently asked questions
What is the fastest linear actuator you make?
The PAI-17-400mm/sec: 400 mm/sec at 200N with 50–900 mm stroke. For more force at speed see the PAI-36-V2-200mm/sec (3000N, 200 mm/sec).
What is the slowest?
The PAI-01-V1-3mm/sec at 6000–8000N. Slow models give the most force.
How do I convert 8.4 in/min to mm/sec?
Multiply by 0.423: 8.4 in/min is about 3.6 mm/sec.
Can I control the speed of a linear actuator?
Yes, lower it with a PWM speed controller or a control box with soft start and stop. Rated speed is the maximum.
Does speed drop under load?
Yes. DC actuators slow down as load rises. The listed speeds are rated values; ask for the curve for your model.
Need help choosing a linear actuator?
Send your load (N or kg), speed (mm/sec), stroke length (mm), voltage and application. Our Bengaluru team will recommend the right model and send a quotation.
Request a quotation