PURLIN AUTOMATION / BLOG / Engineering
Engineering

Linear Actuator Duty Cycle Explained: What a 10% Rating Really Means

By Purlin Automation Engineering Team3 min read
Linear Actuator Duty Cycle Explained: What a 10% Rating Really Means

Duty cycle is the most misunderstood number on an actuator datasheet. A 10% rating does not mean the actuator is weak. It is a limit on how long the motor can run before it must rest and cool down. Getting it wrong is the most common cause of early failure.

Key points
  • 10% = about 1 min running, 9 min rest
  • Overheating, not wear, ends most short lives
  • Continuous motion needs a different design

What duty cycle means

Duty cycle is the percentage of time an actuator can run within a given period. Purlin linear actuators are rated at 10%. In practice that means about 1 minute of running followed by about 9 minutes of rest, or 2 minutes running in any 20-minute window.

The limit exists because of heat. The DC motor, gearbox and lead screw all turn electrical energy into some heat as well as motion. A compact actuator has a small body to get rid of that heat, so it needs rest time to cool.

How to calculate the duty cycle of your application

Use this simple formula:

Duty cycle (%) = running time ÷ (running time + rest time) × 100

Examples:

ApplicationRunningRestDuty cycleOK at 10%?
Height-adjustable desk, 4 moves per hour of 15 s each60 s3540 s1.7%Yes
Hospital bed back-rest, 20 s every 5 minutes20 s280 s6.7%Yes
Solar tracker, small step every 10 minutes8 s592 s1.3%Yes
Packing machine pusher, 4 s on, 6 s off, all day4 s6 s40%No

Most furniture, medical and solar uses sit well below 10%. Industrial machines that cycle every few seconds usually do not.

What happens when you exceed it

  • Motor overheating. Winding insulation ages quickly at high temperature, and brushes and the commutator wear faster.
  • Gear and nut wear. Plastic gears and drive nuts soften as they heat, so they wear and lose accuracy.
  • Thermal cut-out trips. If an actuator stops mid-travel and works again after a rest, it is often overheating.
  • Short life. An actuator run at four times its rated duty cycle can fail in weeks instead of years.

Load and temperature matter too

The 10% rating assumes normal room temperature and a load within the rating. Running at full rated load, or in a hot enclosure, makes the motor heat faster. If your actuator works near its maximum force and moves often, choose a stronger model so it runs below full load, or add longer rest periods in your control program.

Protect it in your controller

If you control the actuator from a PLC, Arduino or microcontroller, you can enforce the duty cycle in software:

  1. Track total running time over a rolling window, for example 10 minutes.
  2. Block new movements once running time reaches 60 seconds in that window.
  3. Show the operator a "cooling, please wait" status instead of failing silently.

Our control boxes are designed for intermittent use and pair with our power supplies, so the whole system is sized for linear-motion duty cycles.

When you need more than 10%

If your machine really needs continuous or near-continuous motion, tell us at the start. Options include a larger motor, a stronger model running at a lower share of its rated load, or a different drive. Send us your cycle times and we will check them before you order.

Products mentioned in this article

Made in Bengaluru. Click a product for full specifications, drawings and datasheets.

Frequently asked questions

What does a 10% duty cycle mean on a linear actuator?

It means the actuator can run for about 10% of the time, for example about 1 minute of running followed by about 9 minutes of rest.

What happens if I run an actuator beyond its duty cycle?

The motor overheats, which ages the insulation, wears gears and the drive nut faster, can trip a thermal cut-out and greatly shortens the actuator's life.

How do I calculate duty cycle?

Divide the running time by the total time (running plus rest) and multiply by 100. For example, 20 seconds of running every 5 minutes is 20 / 300 × 100 = 6.7%.

Share: WhatsApp LinkedIn Facebook X Email
Need help choosing an actuator?

Send us your load, stroke, speed and how often it moves. Our engineers in Bengaluru will recommend a model and send a quotation.

Send an inquiry